6Setup Procedures
6-15
UPC/EAN Addons (SUPPLEMENTS)
Decoder
ON Enable reading UPC & EAN supplements.
OFF* Disable reading UPC & EAN supplements.
2 Digit
ON* Enable reading 2 digit supplements. Decoder must be set ON.
OFF Disable reading 2 digit supplements.
5 Digit
ON* Enable reading 5 digit supplements. Decoder must be set ON.
OFF Disable reading 5 digit supplements.
Required
Specifies how the reader handles various supplements.
OFF * UPC/EAN bar codes are read with or without valid supplements.
UPC UPC bar codes are not read unless they are accompanied by a valid supplement.
EAN EAN bar codes are not read unless they are accompanied by a valid supplement.
BOOKLD Bookland EAN bar codes are not read unless they are accompanied by a valid
supplement.
ALL UPC/EAN bar codes are not read unless they are accompanied by a valid supplement.
Send Space
ON Insert a space between the standard bar code data and the supplemental data.
OFF* No separator space is inserted.
I 2 OF 5
Decoder
ON* Enable reading INTERLEAVED 2 of 5 labels.
OFF Disable reading INTERLEAVED 2 of 5 labels.
Check Digit
Specifies which type of check digit is used with INTERLEAVED 2 of 5:
NONE* NONE (no check digit required)
USS UNIFORM SYMBOLOGY SPECIFICATION (3-1-3 MOD 10)
OPCC OPTICAL PRODUCT CODE COUNCIL (2-1-2 MOD 10)
Send Check ( Digit)
ON Transmit the INTERLEAVED 2 of 5 check digit with the bar code data.
OFF* The check digit is not transmitted.